The titan low-base has a spherical aberration corrector (CEOS Company) at the condenser lens, the lens that forms the probe. It is therefore ideal for ultra-high resolution imaging in Scanning-Transmission mode (HRSTEM) and chemical composition mapping with atomic resolution by Electron Energy Loss Spectroscopy (STEM-EELS).
 
It has a monochromator and a High Brightness source (XFEG), which makes it ideal for optical properties studies by low-loss EELS and oxidation states studies by core-loss EELS and observation of the fine structure of the energy absorption edges by Energy Loss Near Edge Spectroscopy (ELNES).
 
Working at low-voltage, and because of the aberration corrector, we can obtain high resolution images even on beam-sensitive materials such as graphene, carbon nanotubes, zeolites and mesoporous materials…
 
The working voltages for this instrument are: 60, 80, 120, 200 and 300 kV.
 
 

What can be done with it?

Image (0.07nm resolution):

  • Size, morphology and Crystalline Structure information  (TEM and STEM modes, electron diffraction).
  • Composition: Scanning-Transmission Imaging with a High Angle Annular Dark Field detector (STEM-HAADF). The contrast in the image depends on the atomic number (Z-contrast). Energy Filtered TEM (EFTEM) yields information about a specific element.
  • 3D reconstruction: Electron tomography.

 

Chemical Analysis:

  • X-Ray (EDS) and Electron Energy Loss Spectroscopies (EELS).
  • Combined with the STEM mode: chemical composition with spatial resolution: composition maps and profiles with atomic resolution.

 

Vector Field analysis:

  • Electric and magnetic field studies by Electron Holography.
  • Magnetic domain studies: Lorentz Microscopy.
  • Stress and strain studies by HRTEM imaging.

 

In-Situ physical properties measurements:

  • Changes of crystalline phase (Electron diffraction).
  • Defect structure by bright field/dark field imaging (BF/DF) and Weak Beam imaging (WBDF). 

 

Especificaciones técnicas

This Scanning Transmission Electron Microscope works either in TEM or in STEM modes at voltages between 60 and 300 kV. It can be used at low voltage to analyse electron irradiation sensitive materials. It is fitted with the last generation of a high brightness Schotky emitter developed by FEI (the so called “X-FEG” gun), a monochromator, and a Gatan 2k x 2k CCD camera.
 
  • STEM: As this microscope is devoted for STEM and EELS experiments, it is equipped with a CESCOR Cs-probe corrector from CEOS Company allowing for the formation of an electron probe of 0.09 nm mean size. The TEM is equipped with all the STEM facilities (BF, DF, ADF and HAADF detectors) and 0.09 nm spatial resolution has indeed been achieved in STEM-HAADF mode.
  • EELS and EDS: For EELS experiments, the microscope is fitted with a Gatan Energy Filter Tridiem 866 ERS and a monochromator. An energy resolution of 0.14 eV can be achieved with this setup. In addition, an EDS (EDAX) detector allows performing EDX experiments in scanning mode with a spatial resolution of about ~0.2 nm.
  • Lorentz and holography: in addition to the above described analytical capabilities, the Titan STEM corrected microscope is fitted with a Lorentz lens and an electrostatic biprism allowing Lorentz and medium resolution electron holography experiments to be carried out in a field-free environment (as needed for magnetic materials studies).
  • Tomography: a tomography set-up with a +/- 70° single tilt stage permits to perform 3D reconstructions either in TEM or STEM modes.